Find Heat Meter, Single Jet Heat Meter, Mechanical Heat Meter on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > Heat Meter > Single Jet Mechanical Heat Meter with M-Bus or RS-485

Single Jet Mechanical Heat Meter with M-Bus or RS-485

Productivity: 
50, 000/Month
Place of Origin: 
China
Supply Ability: 
50, 000/Month
Certificate: 
CE, ISO9001

Basic Info

Model No.:  YG-RLM(D)-15

Product Description

Model NO.: YG-RLM(D)-15 Installation: Direct Connected Electric Equipment: Battery 8 Years Power Meter Connection: Kw/H, Gcal Type: Heat Meter Customized: Customized Size: Dn15mm, Dn20mm and Dn25mm Body Material: Brass Voltage for M-Bus: 3.6V Communication: M-Bus or RS-485, Infrared Port Flow Rate: Qn = 0.6m3/H or Qn = 1.5m3/H for Choice Specification: Class 2 HS Code: 9028109000 Display: Digital Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter Theory: Electric Apparatus Measured Signal: M-Bus or RS-485 for Choice Certification: CE, ISO9001 Voltage for RS-485: 15V to 24V for Russia Accuracy: Class 2 Logo for OEM: Acceptable Measurement: Kw/H, Gcal Label or Nameplate: English or Russia for Option Trademark: YG or OEM Origin: China  
Single Jet Mechanical Heat Meter with M-Bus or RS-485

Description:

 

YG-RLM (D) series of heat meters are a new generation of integrated single-flow heat meters developed on the basis of YG-RLM series for the Europe and Russia market. This product uses advanced nonmagnetic technology and has the features of simple structure, 

compact size, elegant design, and light weight. It can be used to measure the flows of both heating and cooling systems in living areas. 

The temperature range is 4~95ºC.

 

Models and Specifications

 

Model

Qn(m3/h)

Length(mm)

  DN(mm)

Sensor length 

   Display

Romote

   Class

RLM(D)-15-0.6

    0.6

       110

      15

1.5m

    kw/h

M-BUS

      2

RLM(D)-15-0.6

    0.6

       110

      15

1.5m

    Gcal

RS-485

      2

RLM(D)-15-1.5

    1.5

       110

      15

1.5m

    kw/h

M-BUS

      2

RLM(D)-15-1.5

    1.5

       110

      15

1.5m

    Gcal

RS-485

      2

RLM(D)-20-2.5

    2.5

       130

      20

1.5m

    kw/h

M-BUS

      2

RLM(D)-20-2.5

    2.5

       130

      20

1.5m

    Gcal

RS-485

      2

RLM(D)-25-2.5

    2.5

       160

      25

1.5m

    kw/h

M-BUS

      2

RLM(D)-25-2.5

    2.5

       160

      25

1.5m

    Gcal

RS-485

      2


Features:
1. Flow-rate range: 0.6~2.5m3/h.
2. Min. temperature difference 3ºC
3. Horizontal/vertical installation
4. Embedded and removable installation design to prevent damage during the adjustment period
5. Smart multi-flow design, capable of recording flow rate and volume
6. Advanced nonmagnetic sensing technology
7. High precision design, meeting Class 2 metering requirements of EN1434 and CJ128 standards
8. A lithium battery with service life exceeding six years
9. Optional remote RS485 or M-BUS output, convenient for remote systems
10. Payment settlement date renewable, 18-month data storage
11. 360 degree revolving monitor for easy reading
12. Inclined LCD for optimized viewing
13. Wide measuring range (q s/q i =100:1)
14. Low startup flow rate
15. Capable of measuring both heat and cold energies
16. For use at water inlet end (heat meters for return water end are available at the request of users)
17. PT1000 temperature sensor pair
18. Environment class: A

Main Technical Parameters:  

Normal Flow(Qn)

0.6m3/h

1.5m3/h

2.5m3/h

Flow range(m3/h)

0.012~1.2

0.03~3

0.05~5

  Pressure loss(KPa/Qp)

Reference diagram I

     24

         24

        24

Start flow(L/h)

      3

         5

         7

Max. Pressure(MPa)

                          1.6

Temperature range(ºC)

                         4~95

        Measuring Features:
1.Water pressure: No more than 1Mpa
2.Measuring Class & Max. Tolerance
This product is for Class 2 measurement, and the max tolerance is shown in the curve below: 
E=±(3+4Δθmin/Δθ+0.02qp/q)%
Therein, Δθmin means the minimum temperature difference, and Δθ the actual temperature difference.

Dimensional Parameters:  

Normal flow(Qn)

m3/h

0.6

1.5

2.5

Normal DN

mm

15

15

20

Body thread

----

G3/4"B

G1"B

G3/4"B

G1"B

G1"B

G1 1/4"B

Connection thread

----

1/2"

3/4"

1/2"

3/4"

3/4"

1"

Height

mm

112

115.5

112

115.5

115.5

119.5

Length

mm

110

110

110

110

130

130

  Pressure Loss Diagram:  
Single Jet Mechanical Heat Meter with M-Bus or RS-485


Pipeline Installation Diagram (for Meters Used at Inlet or Outlet for
option) 


Single Jet Mechanical Heat Meter with M-Bus or RS-485
 

If you are interested in our heat meter, please feel free to contact us!
     
      NINGBO YONGGANG INSTRUMENT CO.,LTD
Contact: Ethan Huang
Mobile: 0086-18958354682
Tel: 0086-574-63578074
Fax: 0086-574-63577818
Website: http://en.china-yonggang.com
 

Contact us if you need more details on Heat Meter. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about Single Jet Heat MeterMechanical Heat Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Heat Meter